DCTXV
1、Applicable refrigerant: HFC-134a/HFC-1234yf;
2、Using oil: PAG/POE;
3, the use of environmental temperature: -40 ℃ ~ 120 ℃;
4, action mode: according to the temperature of the sensing part and the pressure of the low pressure side to control the refrigerant flow;
5、Adjustment mechanism: adjusted by the adjustment screw inside the valve body, adjusted in the clockwise direction, the superheat increases, and adjusted in the counterclockwise direction, it decreases;
6、Filling method: gas filling/cross filling;
7、Installation part: evaporator assembly;
8、Installation status: should not be installed towards the bottom, allowing lateral rotation of 90° from the bottom towards the top;
9, Action type: normally open / normally closed;
10、Rated voltage: DC12V;
11, coil power: 10W or less;
12、Operating voltage range: 9V-16V;
13, external leakage: <2g/年@2.0MPa;
14, solenoid valve internal leakage: ≤ 100mL / min at 10.3bar;
15, insulation resistance: > 10MΩ 1min (DC500V);
16, the maximum differential pressure of the open valve: ≥ 22bar (ambient temperature 20.5 ℃, open valve voltage 9V);
17, installation interface dimensions see annex.