This product is used in CNG systems to enable automated control of fueling dispensers. The solenoid valve is normally closed; it opens when the fueling nozzle is lifted and automatically closes when the nozzle is returned to its holder. Its operating principle is as follows: when the coil is energized, the electromagnetic core is attracted, opening the pressure relief orifice. The main piston is then actuated by the medium pressure, opening the main valve port and allowing the medium to flow. When power is cut off, the valve closes.
Technical Specifications
Working Medium: Air, Natural Gas
Orifice Diameter: 8 mm
Rated Working Pressure: 25 MPa
Operating Voltage: 198–242 V